Modbus/TCP - EV line

Modbus/TCP - EV line

This page describes the Modbus register table exposed for Smappee EV charging stations.

See the Modbus TCP/IP main page for connection, configuration, supported function codes and read/write semantics.

 

Connector identification

The list of connectors is configured in the “Configuration” view of the ModbusTCP app. Each connector is exposed under the slave id corresponding to its position in the list (the first connector becomes slave id 1, the second slave id 2, …).

Example: with the configuration above, connector 6021001516-1 is available under slave id 1 and connector 6021001516-2 under slave id 2.

modbustcp-app-config.jpeg

 

General registers

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Notes

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Notes

Manufacturer

1

5

R

ASCII

-

e.g. "Smappee NV"

Station article number

10

-

R

ASCII

-

e.g. "EVUE-240S-C3-B"

Station serial number

20

-

R

ASCII

-

e.g. 62010000050

AC or DC charging station

30

-

R

UNSIGNED16

-

0 = AC, 1 = DC

ID of this connector

31

1

R

UNSIGNED16

-

EV Base / EV Ultra Dual have 2 connectors

Maximum current of this connector (installation)

32

2

R

FLOAT

A

AC charging station

Maximum power of this connector (installation)

34

2

R

FLOAT

W

DC charging station

 

Energy measurements

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Active power L1

101

2

R

FLOAT

W

Active power L2

103

2

R

FLOAT

W

Active power L3

105

2

R

FLOAT

W

Total active power

107

2

R

FLOAT

W

Current L1

109

2

R

FLOAT

A

Current L2

111

2

R

FLOAT

A

Current L3

113

2

R

FLOAT

A

Total current

115

2

R

FLOAT

A

Active energy L1

117

2

R

FLOAT

Wh

Active energy L2

119

2

R

FLOAT

Wh

Active energy L3

121

2

R

FLOAT

Wh

Total active energy

123

2

R

FLOAT

Wh

 

Status and transaction registers

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Notes

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Notes

EVSE state

251

1

R

UNSIGNED16

-

0=A0, 1=A1, 2=A2, 3=B0, 4=B1, 5=B2, 6=B3, 7=B4, 8=B5, 9=B6, 10=B8, 11=B9, 12=B12, 13=C1, 14=C2, 15=C6, 16=C7, 17=C8, 18=C9, 19=C12, 20=D1, 21=D2, 22=E, 23=F

Charging state

252

1

R

UNSIGNED16

-

0=AVAILABLE, 1=CABLE_CONNECTED, 2=CHARGING, 3=PAUSED, 4=CHARGING_ENDED, 5=ERROR, 6=BOOTING, 7=UNAVAILABLE, 99=UNDEFINED

Pause session

255

1

R/W

UNSIGNED16

-

0 = not paused, 1 = paused. AC charging station only.

Stop session

256

1

R/W

UNSIGNED16

-

0 = do not stop, 1 = stop session. DC charging station only.

Current setpoint

257

2

R/W

FLOAT

A

AC charging station

Power setpoint

259

1

R/W

UNSIGNED16

kW

DC charging station

State of charge

260

1

R

UNSIGNED16

%

DC charging station

Number of phases used

261

1

R

UNSIGNED16

-

AC charging station with phase switching enabled. One of 1, 3.

 

Session registers

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Notes

Description

Start address

# of 16-bit registers

R/W

Data type

Unit

Notes

Current session start time

501

2

R

UNSIGNED32

s

Seconds since epoch

Current session duration

503

2

R

UNSIGNED32

s

e.g. 3450

Current session total energy

505

2

R

UNSIGNED32

Wh

e.g. 25470

Previous session start time

523

2

R

UNSIGNED32

s

Seconds since epoch

Previous session stop time

525

2

R

UNSIGNED32

s

Seconds since epoch

Previous session duration

527

2

R

UNSIGNED32

s

e.g. 2500

Previous session total energy

529

2

R

UNSIGNED32

Wh

e.g. 35470