General registers
Description | Start address | # of 16-bit registers | R/W | Data type | Unit | Notes |
|---|---|---|---|---|---|---|
Manufacturer | 1 | 5 | R | ASCII | - | e.g. |
Station article number | 10 | - | R | ASCII | - | e.g. |
Station serial number | 20 | - | R | ASCII | - | e.g. |
AC or DC charging station | 30 | - | R | UNSIGNED16 | - |
|
ID of this connector | 31 | 1 | R | UNSIGNED16 | - | EV Base / EV Ultra Dual have 2 connectors |
Maximum current of this connector (installation) | 32 | 2 | R | FLOAT | A | AC charging station |
Maximum power of this connector (installation) | 34 | 2 | R | FLOAT | W | DC charging station |
Energy measurements
Description | Start address | # of 16-bit registers | R/W | Data type | Unit |
|---|---|---|---|---|---|
Active power L1 | 101 | 2 | R | FLOAT | W |
Active power L2 | 103 | 2 | R | FLOAT | W |
Active power L3 | 105 | 2 | R | FLOAT | W |
Total active power | 107 | 2 | R | FLOAT | W |
Current L1 | 109 | 2 | R | FLOAT | A |
Current L2 | 111 | 2 | R | FLOAT | A |
Current L3 | 113 | 2 | R | FLOAT | A |
Total current | 115 | 2 | R | FLOAT | A |
Active energy L1 | 117 | 2 | R | FLOAT | Wh |
Active energy L2 | 119 | 2 | R | FLOAT | Wh |
Active energy L3 | 121 | 2 | R | FLOAT | Wh |
Total active energy | 123 | 2 | R | FLOAT | Wh |
Status and transaction registers
Description | Start address | # of 16-bit registers | R/W | Data type | Unit | Notes |
|---|---|---|---|---|---|---|
EVSE state | 251 | 1 | R | UNSIGNED16 | - |
|
Charging state | 252 | 1 | R | UNSIGNED16 | - |
|
Pause session | 255 | 1 | R/W | UNSIGNED16 | - |
|
Stop session | 256 | 1 | R/W | UNSIGNED16 | - |
|
Current setpoint | 257 | 2 | R/W | FLOAT | A | AC charging station |
Power setpoint | 259 | 1 | R/W | UNSIGNED16 | kW | DC charging station |
State of charge | 260 | 1 | R | UNSIGNED16 | % | DC charging station |
Number of phases used | 261 | 1 | R | UNSIGNED16 | - | AC charging station with phase switching enabled. One of |
Session registers
Description | Start address | # of 16-bit registers | R/W | Data type | Unit | Notes |
|---|---|---|---|---|---|---|
Current session start time | 501 | 2 | R | UNSIGNED32 | s | Seconds since epoch |
Current session duration | 503 | 2 | R | UNSIGNED32 | s | e.g. |
Current session total energy | 505 | 2 | R | UNSIGNED32 | Wh | e.g. |
Previous session start time | 523 | 2 | R | UNSIGNED32 | s | Seconds since epoch |
Previous session stop time | 525 | 2 | R | UNSIGNED32 | s | Seconds since epoch |
Previous session duration | 527 | 2 | R | UNSIGNED32 | s | e.g. |
Previous session total energy | 529 | 2 | R | UNSIGNED32 | Wh | e.g. |